The fact is that the only regular health analysis is not enough, as the time interval between two checkups is sufficient to damage the disk and affect the all over RAID. There are several ways to monitor or check the health status of hard disks, But here we will discuss the easiest and simplest ways for Hard disk Health check and repair.

Hard drive manufacturers have their own traditional monitoring tool to track hard drive health and performance. Follow the below-given steps to monitor the tool for the hard disk. The in-built Windows utility scans the disks to locate system errors. This integrated utility scans and solves the issues, if possible, or else reports them.

If you Check hard drive health at regular intervals then you can reduce the bad disk health status. WMIC is a command-line interface that controls and checks the S. It gives you an easy conclusion in the form of OK or Pred Fail. This inbuilt feature is a basic command and has only limited information. Traditional or Native SATA hard drives are a cost-friendly way to keep data like pictures, videos, and various other file types.

SSDs work in a quite different way, and they never require defragmentation because the fragmentation connects to where the data is physically kept on the drive, which is not a factor on SSD. And they are required to optimize sometimes.

If you find your non-SSD hard drive is performing slow, then check to see how fragmented it is. Simply type defrag into the Start menu then go to Defragment and Optimise Drives, then choose the drive and press on Analyse. Once the fragmentation is detected, Press on Optimise for that drive. If the system crashes, then the machine needs to be rebooted, and your RAID might be out of sync for important files such as the registry data -suddenly you're in a world of pain as the system tries to not only make sense of two disparate files, but at the same time trying to resynchronize your array.

Each time you write data to it, you need to write twice, and it will slow down the use of the swap. The swap file should be considered something that goes away when you reboot - not something that you need to protect by using a RAID mirror. If you don't see it, you might want to right click and: reactivate the disk.

This can "refresh" the current stage of the process. As to seeing the percent completion of the resync, it will show up automatically in the Disk Management screen in time. It seems to take minutes of resynching before it shows a status; after that it will show a percent completion. Sign up to join this community. The best answers are voted up and rise to the top. Stack Overflow for Teams — Collaborate and share knowledge with a private group. Create a free Team What is Teams?

Learn more. How to view status of software RAID 1 resynching? Ask Question. Asked 11 years, 11 months ago.

Active 5 years, 3 months ago. Viewed k times. How can I check what the exclamation mark means? Improve this question. Just a word of caution to those who are using Windows or Windows 7 software raid, it will not notify you when a drive in the RAID fails: eventlogblog. Add a comment. Active Oldest Votes. Good luck. Improve this answer. Eric Grange 1 1 gold badge 3 3 silver badges 10 10 bronze badges. Or you can just wait. I find the sync has to have been going for minutes before it will give you a percentage complete.

On Windows 10 the option is not there, but you can hit F5 to request a refresh, the percentage should then show up AFTER a few seconds. Here is a summary for anyone searching on this thread and has concerns about this problem. The resynching applies to the whole disk, not just one partition or used portion. SeptimusFry SeptimusFry 1 1 silver badge 3 3 bronze badges.

The type can be: hbaport , subsystem , controller , drive , LUN , or tportal. Syntax reenumerate Reenumerates objects of the specified type. Syntax Parameters Parameter Description subsystems Queries the provider to discover any new subsystems that were added in the currently selected provider.

Syntax rem Used to comment scripts. Syntax Parameters Parameter Description controller Resets the controller. Syntax Parameters Parameter Description object Specifies the type of object to select, including: provider , subsystem , controller , drive , or LUN.

Selecting an HBA port deselects any selected initiator adapters and initiator portals. If no initiator adapter is specified, the command displays the currently selected initiator adapter if any.

Specifying an invalid initiator adapter index results in no in-focus initiator adapter. Selecting an initiator adapter deselects any selected HBA ports and initiator portals.

If no initiator portal is specified, the command displays the currently selected initiator portal if any. Specifying an invalid initiator portal index results in no selected initiator portal.

If no provider is specified, the command displays the currently selected provider if any. Specifying an invalid provider index results in no in-focus provider. If no subsystem is specified, the command displays the subsystem with focus if any. Specifying an invalid subsystem index results in no in-focus subsystem. Selecting a subsystem implicitly selects its associated provider. If no controller is specified, the command displays the currently selected controller if any.

Specifying an invalid controller index results in no in-focus controller. Selecting a controller deselects any selected controller ports, drives, LUNs, target portals, targets, and target portal groups. If no port is specified, the command displays the currently selected port if any. Specifying an invalid port index results in no selected port.

If no drive is specified, the command displays the currently selected drive if any. Specifying an invalid drive index results in no in-focus drive.

Selecting a drive deselects any selected controllers, controller ports, LUNs, target portals, targets, and target portal groups. Selecting a LUN deselects any selected controllers, controller ports, drives, target portals, targets, and target portal groups.

If no target portal is specified, the command displays the currently selected target portal if any. Specifying an invalid target portal index results in no selected target portal. Selecting a target portal deselects any controllers, controller ports, drives, LUNs, targets, and target portal groups. If no target is specified, the command displays the currently selected target if any. Specifying an invalid target index results in no selected target. Selecting a target deselects any controllers, controller ports, drives, LUNs, target portals, and target portal groups.

If no target portal group is specified, the command displays the currently selected target portal group if any. Specifying an invalid target portal group index results in no in-focus target portal group. Search for:. For scripting only. Adds to or replaces the list of controllers that are associated with the currently selected LUN.

Adds to or replaces the list of controller ports that are associated with the currently selected LUN. Use with the controllers or targets parameter. Use with the ports parameter. Specifies the number of the plex to remove. Specifies a target in the currently selected subsystem to associate with the secret.

Specifies an initiator iSCSI name to associate with the secret. Creates a LUN using the automagic hints currently in effect. Specifies the total LUN size in megabytes. Specifies the size in megabytes for a stripe or raid LUN. Lists detailed information about the currently selected LUN, including the contributing drives.

Removes controllers from the list of controllers that are associated with the currently selected LUN. Removes controller ports from the list of controller ports that are associated with the currently selected LUN. For use with the controllers or targets parameter. For use with the ports parameter. Specifies the size in megabytes to extend the LUN. If specified, sets the currently selected target to the VSS import target for the currently selected subsystem.

Specifies the load balance policy. Lists summary information about all iSCSI initiator portals in the currently selected initiator adapter. Lists summary information about each provider known to VDS. Lists summary information about each subsystem in the system. Lists summary information about each controller in the currently selected subsystem.

Lists summary information about each controller port in the currently selected controller. Lists summary information about each drive in the currently selected subsystem. Lists summary information about each LUN in the currently selected subsystem. Lists summary information about all iSCSI target portals in the currently selected subsystem. Lists summary information about all iSCSI targets in the currently selected subsystem.